Heart Rhythm ; 2024 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-38458509

RESUMEN

BACKGROUND: Risk stratification in Brugada syndrome (BrS) remains controversial. In this respect, the role of the electrophysiology study (EPS) has been a subject of debate. In some centers, it is common practice to use an implantable loop recorder (ILR) after a negative EPS to help in risk stratification. However, the diagnostic value of this approach has never been specifically addressed. OBJECTIVE: The aim of this study was to describe the baseline characteristics and the main findings of a diagnostic workup strategy with an ILR after a negative EPS in BrS. METHODS: We conducted a retrospective international registry including patients with BrS and negative EPS (ie, noninducible ventricular tachycardia or ventricular fibrillation) before ILR monitoring. RESULTS: The study included 65 patients from 8 referral hospitals in The Netherlands, Spain, and the United Kingdom (mean age, 39 ± 16 years; 72% male). The main indication for ILR monitoring was unexplained syncope/presyncope (66.2%). During a median follow-up of 39.0 months (Q1 25.0-Q3 47.6 months), 18 patients (27.7%) experienced 21 arrhythmic events (AEs). None of the patients died during follow-up. Bradyarrhythmias were the most common finding (47.6%), followed by atrial tachyarrhythmias (38.1%). Only 3 patients presented with ventricular arrhythmias. AEs were considered incidental in 12 patients (66.7%). In 11 patients (61.1%), AEs led to specific changes in treatment. CONCLUSION: The use of ILR after a negative EPS in BrS is a safe strategy that reflected the high negative predictive value of EPS for ventricular arrhythmia in this syndrome. In addition, it allowed the detection of AEs in a significant proportion of patients, with therapeutic implications in most of them.

2.
Rev. esp. cardiol. (Ed. impr.) ; 77(3): 243-253, mar. 2024. graf, tab
Artículo en Español | IBECS | ID: ibc-231061

RESUMEN

Introducción y objetivos La monitorización a distancia (MD) de los dispositivos cardiacos implantables (DCI) se considera más fiable, eficiente y segura que los convencionales seguimientos presenciales, aunque su implantación es aún subóptima. Este estudio pretende analizar el impacto de la pandemia de COVID-19 en las tasas de implantes y activaciones de MD de DCI en España. Métodos Se utilizó el Registro COVID-19 de MD en España para analizar el número mensual de todos los implantes de DCI y activaciones de MD desde enero de 2018 hasta diciembre de 2021 en España. Se sumaron los datos de los 5 principales fabricantes de DCI y se analizaron de manera descriptiva. Resultados Se registró un total de 205.345 DCI. El número de implantes disminuyó bruscamente (48,2%) con el confinamiento (marzo a junio de 2020) y aumentó progresivamente después hasta compensar la reducción previa, excepto en marcapasos y desfibriladores automáticos implantables (DAI), con una pérdida agregada (2020-2021) del 7 y el 3%, respectivamente, respecto a la media anual. Aumentaron la terapia de resincronización cardiaca con desfibrilador (TRC-D, 17%) y con marcapasos (TRC-P, 4,5%) a los 2 años. El porcentaje de activaciones de MD aumentó del 24,5% en 2018 al 49,0% en 2021, con un fuerte aumento durante el confinamiento. Las tasas de activación de MD aumentaron invariablemente durante el confinamiento con todos los dispositivos: marcapasos (el 14,4 frente al 37,2%; p<0,001); DAI (el 75,6 frente al 94,2%; p<0,001); TRC-D/TRC-P (del 68,6/44,2% al 81,6/61%; p<0,001), y Holters implantables (el 50,2 frente al 68,7%; p<0,001). Conclusiones La significativa reducción de los implantes que se produjo durante el confinamiento se recuperó gradualmente después, excepto los de marcapasos y DAI. La pandemia de COVID-19 impulsó la MD de todos los DCI en España. (AU)


Introduction and objectives Remote monitoring (RM) of cardiac implantable electronic devices (CIEDs) is considered more reliable, efficient, and safer than conventional in-person follow-up. However, the implementation of RM is still suboptimal. This study aimed to analyze the impact of the COVID-19 pandemic on the rates of CIED implants and RM activations in Spain. Methods The COVID-19 RM Spain Registry was used to analyze the monthly number of all CIED implantations and RM activations from January 2018 to December 2021. A descriptive analysis was performed using aggregated data from the five major CIED manufacturers. Results A total of 205 345 CIEDs were recorded. The number of implants decreased sharply (48.2%) during the pandemic lockdown (March-June 2020) but gradually increased thereafter, compensating for the previous reduction. However, pacemakers and implantable cardiac defibrillators (ICD) showed an aggregate loss of 7% and 3%, respectively, from the annual average during 2020-2021. In contrast, cardiac resynchronization therapy defibrillators (CRT-D) increased by 17%, and pacemakers (CRT-P) by 4.5% over the 2-year period. The percentage of RM activations increased from 24.5% in 2018 to 49.0% in 2021, with a sharp increase during the lockdown. The RM activation rates consistently increased during the lockdown for all devices: pacemakers (14.4% vs 37.2%; P<.001); ICD (75.6% vs 94.2%; P<.001); CRT-D/CRT-P (68.6-44.2% vs 81.6-61%; P<.001), and implantable loop recorders (50.2% vs 68.7%; P<.001). Conclusions The significant decline in implants during the lockdown gradually recovered, except for pacemakers and ICD. However, the COVID-19 pandemic boosted RM for all CIEDs in Spain. (AU)


Asunto(s)
Humanos , Marcapaso Artificial , Desfibriladores Implantables , Prótesis e Implantes , /epidemiología , España , Pacientes
3.
Rev Esp Cardiol (Engl Ed) ; 77(3): 243-253, 2024 Mar.
Artículo en Inglés, Español | MEDLINE | ID: mdl-37516312

RESUMEN

INTRODUCTION AND OBJECTIVES: Remote monitoring (RM) of cardiac implantable electronic devices (CIEDs) is considered more reliable, efficient, and safer than conventional in-person follow-up. However, the implementation of RM is still suboptimal. This study aimed to analyze the impact of the COVID-19 pandemic on the rates of CIED implants and RM activations in Spain. METHODS: The COVID-19 RM Spain Registry was used to analyze the monthly number of all CIED implantations and RM activations from January 2018 to December 2021. A descriptive analysis was performed using aggregated data from the five major CIED manufacturers. RESULTS: A total of 205 345 CIEDs were recorded. The number of implants decreased sharply (48.2%) during the pandemic lockdown (March-June 2020) but gradually increased thereafter, compensating for the previous reduction. However, pacemakers and implantable cardiac defibrillators (ICD) showed an aggregate loss of 7% and 3%, respectively, from the annual average during 2020-2021. In contrast, cardiac resynchronization therapy defibrillators (CRT-D) increased by 17%, and pacemakers (CRT-P) by 4.5% over the 2-year period. The percentage of RM activations increased from 24.5% in 2018 to 49.0% in 2021, with a sharp increase during the lockdown. The RM activation rates consistently increased during the lockdown for all devices: pacemakers (14.4% vs 37.2%; P <.001); ICD (75.6% vs 94.2%; P <.001); CRT-D/CRT-P (68.6-44.2% vs 81.6-61%; P <.001), and implantable loop recorders (50.2% vs 68.7%; P <.001). CONCLUSIONS: The significant decline in implants during the lockdown gradually recovered, except for pacemakers and ICD. However, the COVID-19 pandemic boosted RM for all CIEDs in Spain.


Asunto(s)
COVID-19 , Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Marcapaso Artificial , Humanos , Pandemias , COVID-19/epidemiología , Control de Enfermedades Transmisibles
4.
Pacing Clin Electrophysiol ; 47(1): 149-155, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38055612

RESUMEN

BACKGROUND: Conventional right ventricle (RV) pacemaker stimulation has been associated with worse clinical outcomes in patients with cardiac amyloidosis (CA). Left bundle branch area pacing (LABPP) has been suggested as a promising alternative. We sought to assess the safety, feasibility, and outcomes of LABPP in patients with CA. METHODS: We retrospectively analyzed echocardiography and pacing parameters and clinical outcomes in 23 consecutive patients with CA and LBBAP implanted from June 2020 to October 2022. RESULTS: LBBAP was successfully performed in 22 over 23 patients (19 male, 78.6 ± 11.7 years, 20 ATTR, mean LVEF 45.5 ± 16.2%). After the procedure, 9 patients showed Qr pattern and 11 a qR pattern in V1 on ECG. Average procedure time was 67 ± 28 min. After 7.7 ± 5.2 months follow-up, no procedure-related complications had occurred. Although, a significant reduction in QRS width (p = .001) was achieved, we did not observe significant changes in LVEF and Nt ProBNP at 6 months of follow-up. Pacing parameters were stable during follow-up: LBB capture threshold and R wave amplitude were 1.0 ±  0.5 V and 10.6 ± 6.0 mV versus 0.8 ±  0.1 V, p = .21 and 10.6 ± 5.1 mV (p = .985) at follow up. CONCLUSION: LBBAP is safe and feasible pacing technique for patients with CA. LBBAP is associated with significant narrowing of QRSd without worsening in LVEF and Nt-proBNP.


Asunto(s)
Amiloidosis , Tabique Interventricular , Humanos , Masculino , Estudios de Factibilidad , Estudios Retrospectivos , Amiloidosis/terapia , Ventrículos Cardíacos , Electrocardiografía , Estimulación Cardíaca Artificial , Fascículo Atrioventricular , Resultado del Tratamiento
5.
Aging Dis ; 15(1): 408-420, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-37307839

RESUMEN

Catheter ablation is a well-established rhythm control therapy in atrial fibrillation (AF). Although the prevalence of AF increases dramatically with age, the prognosis and safety profile of index and repeat ablation procedures remain unclear in the older population. The primary endpoint of this study was to assess the arrhythmia recurrence, reablation and complication rates in older patients. Secondary endpoints were the identification of independent predictors of arrhythmia recurrence and reablation, including information on pulmonary vein (PV) reconnection and other atrial foci. Older (n=129, ≥70 years) and younger (n=129, <70 years) patients were compared using a propensity-score matching analysis based on age, gender, obesity, hypertension, dyslipidemia, diabetes mellitus, dilated left atrium, severe obstructive sleep apnea, cardiac disease, left systolic ventricular function, AF pattern and ablation technique. Arrhythmia recurrence and reablation were evaluated in both groups using a Cox regression analysis in order to identify predictors. During a 30-month follow-up period, there were no significant differences between older and younger patients in the arrhythmia-free survival (65.1% and 59.7%; log-rank test p=0.403) and complication (10.1% and 10.9%; p>0.999) rates after the index ablation. However, the reablation rate was significantly different (46.7% and 69.2%; p<0.05, respectively). In those patients who underwent reablation procedure (redo subgroups), there were no differences in the incidence of PV reconnection (38.1% redo-older and 27.8% redo-younger patients; p=0.556). However, the redo-older patients had lower reconnected PVs per patient (p<0.01) and lower atrial foci (2.3 and 3.7; p<0.01) than the redo-younger patients. A further important finding was that age was not an independent predictor of arrhythmia recurrence or reablation. Our data reveal that the AF index ablation in older patients had a similar efficacy and safety profile to younger patients. Therefore, age alone must not be considered a prognostic factor for AF ablation but the presence of limiting factors such as frailty and multiple comorbidities.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Anciano , Fibrilación Atrial/epidemiología , Resultado del Tratamiento , Reoperación , Atrios Cardíacos , Ablación por Catéter/efectos adversos
6.
Rev. esp. cardiol. (Ed. impr.) ; 76(11): 922-935, Nov. 2023. tab, graf, mapas
Artículo en Español | IBECS | ID: ibc-226976

RESUMEN

Introducción y objetivos: Se presentan los datos de implantes de desfibrilador automático implantable en España en el año 2022.Métodos: Los datos provienen de los centros implantadores, que cumplimentaron voluntariamente una hoja de recogida de datos durante el implante, a mano o a través de una página web.Resultados: Durante 2022, han participado en el registro 170 hospitales. Se han recibido 7.693 formularios, frente a los 7.970 comunicados por la European Confederation of Medical Suppliers Associations (Eucomed), lo que representa un 96,5% de los dispositivos. La tasa total de implantes registrados fue 162/millón de habitantes (168 según Eucomed), un ligero incremento respecto a años anteriores. Las diferencias entre las comunidades autónomas persisten, así como nuestra última posición respecto a los países europeos que participan en la Eucomed.Conclusiones: Los datos del registro de 2022 reflejan la recuperación completa de la actividad tras el impacto de la pandemia de la COVID-19 en 2020. Pese a la leve mejora, se mantiene nuestra posición en Europa y también las grandes diferencias entre nuestras comunidades autónomas.(AU)


Introduction and objectives: This article presents data on implantable cardioverter-defibrillator implants in Spain in 2022.Methods: The data were collected from implantation centers, which voluntarily completed a data collection sheet during the implantation process, either manually or through a web page.Results: In 2022, 170 hospitals participated in the registry. A total of 7693 forms were received compared with the 7970 reported by Eucomed (European Confederation of Medical Suppliers Associations), representing 96.5% of the devices. The total rate of registered implants was 162/million inhabitants (168 according to Eucomed), showing a slight increase compared with previous years. Disparities persisted among autonomous communities and Spain continued to have the lowest implantation rate among countries participating in Eucomed.Conclusions: The data from the registry for 2022 reflect the complete recovery of activity after the impact of the COVID-19 pandemic in 2020. Despite a slight improvement, there was no significant change in our position in Europe or in the substantial differences among autonomous communities.(AU)


Asunto(s)
Humanos , Masculino , Femenino , Desfibriladores Implantables/estadística & datos numéricos , Muerte Súbita Cardíaca , Sistema de Registros/estadística & datos numéricos , Arritmias Cardíacas , Cardiología , España , Desfibriladores Implantables/tendencias
7.
Pacing Clin Electrophysiol ; 46(10): 1278-1286, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37695204

RESUMEN

BACKGROUND: Embolic cerebrovascular events that remain of unknown etiology after a thorough diagnostic evaluation, are known as Embolic Strokes of Undetermined Source (ESUS). Subclinical atrial fibrillation (AF) represents a significant underlying cause of ESUS. Our aims were to examine the overall diagnostic yield of a prolonged cardiac monitoring wearable system (PCMw) after an ESUS to detect AF and factors associated with it, including the time frame from the ESUS event to PCMw initiation. Additionally, to evaluate the frequency of unexpected arrhythmic events (UAE) and their prognostic implications. METHODS: We retrospectively analyzed 200 ECG recordings (3-leads, 30 days duration) by means of a PCMw in patients with an ESUS to detect AF lasting longer than 30 s, between 2017 and 2021. UAE were defined as arrhythmia events that were not correlated to the main reason of prolonged cardiac monitoring. RESULTS: AF was detected in 21 patients (10.5%). Patients with AF had more left atrial enlargement (OR = 4.22 [1.59-6.85]; p = .01) and atrial arrythmias in the initial 24-h Holter during hospitalization (OR = 5.73 [2.03-16.49]; p = .001). The detection of AF was significatively higher if the PCMw was worn within the first 30 days after the ESUS compared to beyond 30 days (17% vs. 10.3%; p = .002). Fifty three patients (26.5%) had UAE during PCMw. In six of them these findings led to targeted treatment. CONCLUSION: PCMw represents a feasible non-invasive device that could reliably detect subclinical AF episodes after an ESUS. Diagnostic yield was significatively higher when used within the first 30 days after the event, especially in selected patients. UAE were common, but did not impact prognosis.

8.
Rev Esp Cardiol (Engl Ed) ; 76(11): 922-935, 2023 Nov.
Artículo en Inglés, Español | MEDLINE | ID: mdl-37774946

RESUMEN

INTRODUCTION AND OBJECTIVES: This article presents data on implantable cardioverter-defibrillator implants in Spain in 2022. METHODS: The data were collected from implantation centers, which voluntarily completed a data collection sheet during the implantation process, either manually or through a web page. RESULTS: In 2022, 170 hospitals participated in the registry. A total of 7693 forms were received compared with the 7970 reported by Eucomed (European Confederation of Medical Suppliers Associations), representing 96.5% of the devices. The total rate of registered implants was 162/million inhabitants (168 according to Eucomed), showing a slight increase compared with previous years. Disparities persisted among autonomous communities and Spain continued to have the lowest implantation rate among countries participating in Eucomed. CONCLUSIONS: The data from the registry for 2022 reflect the complete recovery of activity after the impact of the COVID-19 pandemic in 2020. Despite a slight improvement, there was no significant change in our position in Europe or in the substantial differences among autonomous communities.


Asunto(s)
Cardiología , Desfibriladores Implantables , Humanos , Arritmias Cardíacas/epidemiología , Arritmias Cardíacas/terapia , Pandemias , Sistema de Registros , España/epidemiología
9.
ESC Heart Fail ; 10(6): 3700-3709, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37731197

RESUMEN

AIMS: Atrial fibrillation (AF) worsens the prognosis of patients with heart failure (HF). Successful treatments are still very scarce for those with permanent AF and preserved (HFpEF) or mildly reduced (HFmrEF) ejection fraction. In this study, the long-term benefits and safety profile of heart rate regularization through left-bundle branch pacing (LBBP) and atrioventricular node ablation (AVNA) will be explored in comparison with pharmacological rate-control strategy. METHODS AND RESULTS: The PACE-FIB trial is a multicentre, prospective, open-label, randomized (1:1) clinical study that will take place between March 2022 and February 2027. A total of 334 patients with HFpEF/HFmrEF and permanent AF will receive either LBBP followed by AVNA (intervention arm) or optimal pharmacological treatment for heart rate control according to European guideline recommendations (control arm). All patients will be followed up for a minimum of 36 months. The primary outcome measure will be the composite of all-cause mortality, HF hospitalization, and worsening HF at 36 months. Other secondary efficacy and safety outcome measures such as echocardiographic parameters, functional status, and treatment-related adverse events, among others, will be analysed too. CONCLUSION: LBBP is a promising stimulation mode that may foster the clinical benefit of heart rate regularization through AV node ablation compared with pharmacological rate control. This is the first randomized trial specifically addressing the long-term efficacy and safety of this pace-and-ablate strategy in patients with HFpEF/HFmrEF and permanent AF.


Asunto(s)
Fibrilación Atrial , Insuficiencia Cardíaca , Humanos , Nodo Atrioventricular/cirugía , Estudios Prospectivos , Volumen Sistólico , Fibrilación Atrial/cirugía , Fibrilación Atrial/complicaciones
11.
Emergencias ; 35(3): 185-195, 2023 Jun.
Artículo en Español, Inglés | MEDLINE | ID: mdl-37350601

RESUMEN

OBJECTIVES: Patients with implantable cardioverter defibrillators (ICDs) are at risk of serious complications that are often treated in hospital emergency departments (EDs). The EMERG-ICD study (Emergency Department Management and Long-term Prognosis for Patients with ICDs) analysed management and long-term prognosis of ED patients with an ICD after an acute clinical event. MATERIAL AND METHODS: Observational multicenter cohort study including consecutive adult patients with ICDs who came to 27 hospital EDs in Spain for treatment and were followed for 10 years. We collected clinical variables on presentation, ED case management variables, and the date and cause of death in each case. The primary outcome variable was all-cause mortality. RESULTS: Five-hundred three patients were studied; 471 had structural heart disease (SHD) and 32 had primary electrical heart disease (PEHD). Beta-blockers were prescribed in the ED for 55% of the patients for whom they were indicated. Twenty-four (4.8%), 75 (15.7%), and 368 (73.2%) patients died during follow-up at 1 month, 1 year, and 10 years, respectively. Of these, 363 (77.1%) had SHD and 5 (15.6%) had PEHD (hazard ratio, 8.05 (95% CI, 3.33- 19.46). Among patients with SHD, the cause of death was cardiovascular in 66%. Mortality correlated significantly with seeking care for cardiovascular symptoms, advanced age, male sex, diabetes, a New York Heart Association score of 2 or more, severe ventricular dysfunction, and long-term amiodarone therapy. CONCLUSION: Prognosis after an acute clinical event is poor in patients with SHD and ICDs, mainly due to cardiovascular causes, especially among patients with associated comorbidities and cardiovascular complaints. Mortality is lower in patients with PEHD.


OBJETIVO: Los pacientes portadores de desfibriladores automáticos implantables (DAI) tienen riesgo de complicaciones graves que son atendidas con frecuencia en los servicios de urgencias hospitalarios (SUH). Este estudio analiza el manejo y el pronóstico de las urgencias en portadores de un DAI. METODO: Estudio de cohorte observacional y multicéntrico que incluyó de manera consecutiva pacientes adultos portadores de DAI que consultaron en 27 SUH en España, con seguimiento posterior a 10 años. Se recogieron las variables clínicas, manejo en el SUH, fecha y causa del fallecimiento. La variable de resultado primaria fue la mortalidad por cualquier causa. RESULTADOS: Se incluyeron 503 pacientes, 471 con cardiopatía estructural (CE) y 32 con enfermedad eléctrica primaria cardiaca (EEPC). Se prescribió betabloqueantes en el SUH al 55% de los pacientes con indicación. Durante el seguimiento fallecieron 24 (4,8%), 75 (15,7%) y 368 pacientes (73,2%) a 1 mes, 1 año y 10 años, respectivamente. De estos, 363 tenían CE y 5 EEPC (77,1% vs 15,6%, HR 8,05 IC 95% 3,33-19,46). Entre los pacientes con CE, la mortalidad global fue de causa cardiovascular en el 66% de los casos. La mortalidad se asoció significativamente con la consulta por una causa cardiovascular, edad avanzada, sexo masculino, diabetes, NHYA 2, disfunción ventricular grave y tratamiento crónico con amiodarona. CONCLUSIONES: El pronóstico de los portadores de DAI con CE es muy adverso, fundamentalmente debido a complicaciones cardiovasculares en pacientes con comorbilidades que consultan por sintomatología cardiovascular. La mortalidad es menor en los pacientes con EEPC.


Asunto(s)
Desfibriladores Implantables , Cardiopatías , Adulto , Humanos , Masculino , Desfibriladores Implantables/efectos adversos , Estudios de Cohortes , Pronóstico , Servicio de Urgencia en Hospital
12.
Pacing Clin Electrophysiol ; 46(7): 598-606, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37310031

RESUMEN

BACKGROUND AND OBJECTIVES: The common practice after atrial fibrillation ablation is to admit patients for an overnight stay. The aim of this study was to compare a strategy of vascular suture mediated closure system utilization and early discharge (strategy A) compared to traditional closure and overnight hospitalization (strategy B) regarding feasibility, safety, quality of life and health care cost effectiveness. METHODS AND RESULTS: Hundred patients were randomized to compare both strategies. No clinical differences were reported except diabetes mellitus. Six patients (6%) had and emergency visit or were admitted in the first 30 days after procedure. Three occurred in strategy A versus three in strategy B (p = 1) (p < .005 for non-inferiority). Forty out of 50 patients (80%) were safely discharged in a time frame of 3 h and 42 patients (84%) were discharged in the same day of the procedure in strategy A. Time to discharge was shorter in strategy A compared to strategy B. (5.89 ± 7.47 h vs. 27.09 ± 2.29 p < .005). No differences were obtained in quality-of-life outcomes. Mean (95% CI) euros cost saving per patient in strategy A was 379.16 ± 93.55 p < .001. Ten acute complications (10% patients CI 95% 4.02%-15.98%) were reported during the trial. Seven (14% CI 95% 4.04%-23.96%) occurred in strategy A patients versus 3 (6% CI 95% 0.8%-12.8%) in strategy B. (p = .182) CONCLUSION: A strategy of vascular suture mediated closure system utilization and early discharge was feasible, reduced time to discharge, saved costs and was not associated with more complications or admissions/emergency visits in a 30-day time frame after procedure compared to a strategy of regular admission and discharge after overnight stay. There were no differences regarding quality-of-life parameters between both strategies.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Alta del Paciente , Calidad de Vida , Hospitalización , Punciones , Resultado del Tratamiento
15.
J Clin Med ; 11(19)2022 Oct 03.
Artículo en Inglés | MEDLINE | ID: mdl-36233729

RESUMEN

Pulmonary vein (PV) isolation is a well-established rhythm control therapy in atrial fibrillation (AF). Currently, there is no consensus on which ablation technique to use for the first procedure, cryoballoon (CB) or radiofrequency (RF). A retrospective cohort study was conducted on 1055 patients who underwent a first ablation, to assess both techniques based on the need for reablation. Patients with CB (n = 557) and RF (n = 498) ablations were clinically characterized and the need for reablation during a 30-month follow-up was used as the primary endpoint. Independent variables were analyzed to identify potential predictors. The need for reablation was significantly lower in the CB group than in the RF group (hazard ratio = 0.45 and 95% confident interval = 0.32−0.61; p < 0.001); in both paroxysmal and persistent AF, using a full-adjusted regression Cox model by age, sex, smoking, hypertension, diabetes mellitus, dyslipidemia, severe obstructive sleep apnea, dilated left atrium, persistent AF and early recurrence. RF ablation, dilated left atrium, persistent AF and early recurrence were identified as independent predictors of reablation. In addition, the CB-redo subgroup had a lower PV reconnection than the RF-redo subgroup. In conclusion, CB ablation suggests a reduction in the need for reablation and lower PV reconnection during the follow-up than RF ablation.

16.
Artículo en Inglés, Español | MEDLINE | ID: mdl-36155845

RESUMEN

INTRODUCTION AND OBJECTIVES: This article presents the data corresponding to implantable cardioverter-defibrillator (ICD) implantations in Spain in 2021. METHODS: The data were drawn from implanting centers, which voluntarily completed a data collection sheet during the procedure. RESULTS: In 2021, 7496 implant data sheets were received, compared with 7743 reported by Eucomed (European Confederation of Medical Suppliers Associations), indicating that data were collected from 96.8% of the devices implanted in Spain. Data completion ranged from 99.9% for "name of implanting hospital" to 8.9% for "implanting hospital". In 2021, 199 hospitals participated in the registry, exceeding the figures of previous years, with around 170 participating hospitals. The total rate of registered implants was 158/million inhabitants (163 according to Eucomed), making 2021 the year with the highest activity. However, the registry continues to show significant differences among the various autonomous communities and the lowest implantation rate of all the European countries participating in Eucomed. CONCLUSIONS: The Spanish implantable cardioverter-defibrillator registry for 2021 recorded an increase in the number of ICD implantations, reflecting the recovery of hospital activity after the initial impact of the COVID-19 pandemic in 2020. Although the total number of implants has increased in Spain, figures are still much lower than the European Union average, with differences persisting among Spanish autonomous communities.

17.
J Electrocardiol ; 74: 26-31, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35917620

RESUMEN

BACKGROUND: Adequate measurement of the QT interval is of clinical importance in order to identify patients at higher risk for ventricular arrhythmias. Previous studies have described different methods to estimate baseline QT in patients with left bundle branch block (LBBB). However, the evidence regarding the assessment of the QT in patients with right bundle branch block (RBBB) is scarce. AIM: To analyze the feasibility and reliability of the different formulae described for LBBB in the estimation of the baseline QT in the presence of RBBB. METHODS: We performed an observational study including patients who underwent electrophysiology study and/or ablation. Two types of RBBB were considered: 1) pacing-induced and 2) transient true RBBB. QRS, JT and QT intervals were measured during baseline and RBBB. Estimated QTc was calculated using LBBB formulae: Bogossian, Rautaharju, Tabatabaei, Tang-Rabkin, Yankelson, Wang. Linear correlation and intraclass correlation coefficients (ICC) were used to assess the reliability of these formulae for the estimation of baseline QTc. RESULTS: We finally included a total of 100 patients. Correlations between baseline and estimated QTc were strong (R > 0.7) for all the formulae except for Tabatabaei. Yankelson and Wang showed the highest reliability (ICC = 0.775 and 0.727, respectively). Yankelson appeared to be the most accurate formula, with a mean estimated QTc closest to baseline values. CONCLUSION: Previously described formulae for LBBB exhibited marked differences regarding reliability in the estimation of the QTc interval in the presence of RBBB. According to our results, Yankelson showed the most consistent and accurate agreement in this setting.


Asunto(s)
Bloqueo de Rama , Electrocardiografía , Humanos , Bloqueo de Rama/diagnóstico , Reproducibilidad de los Resultados
18.
Europace ; 24(11): 1788-1799, 2022 11 22.
Artículo en Inglés | MEDLINE | ID: mdl-35851611

RESUMEN

AIMS: To determine the spectral dynamics of early spontaneous polymorphic ventricular tachycardia and ventricular fibrillation (PVT/VF) in humans. METHODS AND RESULTS: Fifty-eight self-terminated and 173 shock-terminated episodes of spontaneously initiated PVT/VF recorded by Medtronic implanted cardiac defibrillators (ICDs) in 87 patients with various cardiac pathologies were analyzed by short fast Fourier transform of shifting segments to determine the dynamics of dominant frequency (DF) and regularity index (RI). The progression in the intensity of DF and RI accumulations further quantified the time course of spectral characteristics of the episodes. Episodes of self-terminated PVT/VF lasted 8.6 s [95% confidence interval (CI): 8.1-9.1] and shock-terminated lasted 13.9 s (13.6-14.3) (P < 0.001). Recordings from patients with primarily electrical pathologies displayed higher DF and RI values than those from patients with primarily structural pathologies (P < 0.05) independently of ventricular function or antiarrhythmic drug therapy. Regardless of the underlying pathology, the average DF and RI intensities were lower in self-terminated than shock-terminated episodes [DF: 3.67 (4.04-4.58) vs. 4.32 (3.46-3.93) Hz, P < 0.001; RI: 0.53 (0.48-0.56) vs. 0.63 (0.60-0.65), P < 0.001]. In a multivariate analysis controlled by the type of pathology and clinical variables, regularity remained an independent predictor of self-termination [hazard ratio: 0.954 (0.928-0.980)]. Receiver operating characteristic (ROC) curve analysis of DF and RI intensities demonstrated increased predictability for self-termination in time with 95% CI above the 0.5 cut-off limit at about t = 8.6 s and t = 6.95 s, respectively. CONCLUSION: Consistent with the notion that fast organized sources maintain PVT/VF in humans, reduction of frequency and regularity correlates with early self-termination. Our findings might help generate ICD methods aiming to reduce inappropriate shock deliveries.


Asunto(s)
Desfibriladores Implantables , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Arritmias Cardíacas , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/terapia
19.
Rev Esp Cardiol (Engl Ed) ; 75(10): 805-815, 2022 Oct.
Artículo en Inglés, Español | MEDLINE | ID: mdl-35688688

RESUMEN

INTRODUCTION AND OBJECTIVES: Equal opportunities to access technical advances with recognized clinical value should be a priority of the publicly-funded health system. We analyzed variability among all the Spanish autonomous communities in the use of cardiovascular techniques with an established indication and its relationship with economic indicators, burden of disease, and hospital mortality. METHODS: The activity registries of various Associations of the Spanish Society of Cardiology from 2011 to 2019 were analyzed for coronary angiography, overall percutaneous coronary intervention (PCI), primary PCI, implantable cardioverter-defibrillators (ICD), cardiac resynchronization therapy, and transcatheter aortic valve replacement (TAVR). Economic indices (gross domestic product and per capita health care expenditure) were obtained from public sources and data on attendance rates and mortality from the Resources and Quality in Cardiology (RECALCAR) reports of the Spanish Society of Cardiology. We analyzed the coefficient of variation for activity and the correlation of activity with regional economic indices, attendance rates, and risk-adjusted rates of in-hospital mortality. RESULTS: We identified wide variability in the use of technologies, especially for primary PCI (18%), ICD (22%), cardiac resynchronization therapy (36%), and TAVR (42%). A certain correlation with attendance rates was seen only for overall PCI and ICD. In general, no significant correlation was found between the use of the techniques and the economic indices of wealth and expenditure. The correlation with in-hospital mortality showed no significant results, although this was the analysis with the greatest limitations because the impact of these techniques on survival is exerted more in the mid- and long-term. CONCLUSIONS: The results of this study, despite its inherent limitations, show marked variability between autonomous communities in the use of cardiovascular technologies, which is not explained by economic differences or by hospital attendance rates due to the corresponding diseases.


Asunto(s)
Cardiología , Intervención Coronaria Percutánea , Reemplazo de la Válvula Aórtica Transcatéter , Angiografía Coronaria , Mortalidad Hospitalaria , Humanos , Sistema de Registros , Resultado del Tratamiento
20.
Cardiovasc Revasc Med ; 43: 104-111, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35398008

RESUMEN

BACKGROUND: Coronary chronic total occlusion lesions (CTOs) confer an increased risk of arrhythmic events among patients with ischemic cardiomyopathy (ICM) and implantable cardioverter-defibrillator (ICD) carriers, however the impact of CTO recanalization in this population remains unassessed. AIMS: Evaluate the impact of CTOs percutaneous coronary interventions (PCI) on arrhythmic events. METHODS: Patients with ICM and ICD from the VACTO I-II registries: patients with medically treated CTO (CTO-OMT group) and without CTO (no-CTO group) were compared after inverse-probability-weighting adjustment (IPWT) with a similar population of consecutive patients undergoing CTO-PCI. The primary endpoint was appropriate ICD therapy. The secondary endpoint was all-cause mortality. RESULTS: The total of 622 patients (mean age 67 ± 10 years, mean left ventricular ejection fraction 36 ± 11%) included in the analysis was composed by: CTO-PCI patients n = 113, CTO-OMT patients n = 286, no-CTO patients n = 223. In the CTO-PCI group, compared to the CTO-OMT group, 5-year Kaplan Meier estimates for appropriate ICD therapy (20.4% vs. 56.4%, IPW-adjusted HR: 0.45, 95% CI 0.29-0.71) and mortality (8.8% vs. 23%, IPW-adjusted HR: 0.43, 95% CI 0.22-0.85) were lower, driven by infarct related artery CTO (IRA-CTO) PCI, while similar to those occurring in the no-CTO group. CONCLUSIONS: In this large population, those with CTO receiving PCI had lower arrhythmic event rates and lower mortality compared to the CTO-OMT group, while showing an event rate similar to no-CTO patients. Sensitivity analyses suggest that the beneficial effect on the arrhythmic outcome was driven by IRA-CTO revascularization. CLASSIFICATION: Chronic total occlusion.


Asunto(s)
Cardiomiopatías , Oclusión Coronaria , Desfibriladores Implantables , Intervención Coronaria Percutánea , Anciano , Arritmias Cardíacas/terapia , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/terapia , Enfermedad Crónica , Oclusión Coronaria/complicaciones , Oclusión Coronaria/diagnóstico por imagen , Oclusión Coronaria/terapia , Humanos , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Factores de Riesgo , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda